Engineering specs for home hydroponics & backyard greenhouses

Size greenhouse heating, exhaust airflow, leaf VPD & dew point, canopy DLI lighting, reservoir dosing, and pump head on one shared SI equation set.

Explore all 6 calculators

Engineering calculators

Six browser calculators calibrated against one shared thermal, psychrometric, optical, chemical, and hydraulic model.

All 6 calculators
Engineering schematic of greenhouse conduction heat loss, air-infiltration loss, and heater circuit load budget Lean-to wall excluded Envelope U + ACH Q = Sum(A*U*dT) + 0.335*V*ACH*dT Total circuit load

Greenhouse heating load & circuit budget calculator

Size winter greenhouse heat loss in BTU/h and watts, verify breaker amps, and estimate overnight heating cost from heater electrical watts and thermostat runtime.

Open calculator
Engineering schematic of greenhouse low intake louver, canopy crossflow, exhaust fan, and static pressure curve Louver + Mesh Exhaust Q-P A_net = Q / v_face

Greenhouse exhaust ventilation & intake area calculator

Estimate exhaust CFM (m³/h), size louvered or screened intakes from face velocity curves without double-deducting mesh area, and confirm fan output on the Q-P curve.

Open calculator
Engineering schematic of leaf VPD temperature-by-humidity corridor, setpoint marker, and cold glazing dew-point check T × RH Corridor Leaf VPD 0.4–1.25 VPD_leaf = SVP(T_leaf) - AVP Cold glass > dew pt Magnus-Tetens T_dew

Greenhouse VPD & dew-point condensation calculator

Enter air temperature, RH, and measured leaf temperature (or offset) to read Leaf VPD, Air VPD, and Dew Point side-by-side with cold-surface condensation checks.

Open calculator
Engineering schematic of overhead LED photon cone, canopy capture ratio, and natural versus supplemental DLI gauge Capture & PPE DLI_supp = max(0, Target - Nat) PPFD = DLI / (h * 0.0036) W = (PPFD * A / eta) / PPE

Grow light PPFD, DLI & canopy wattage calculator

Calculate DLI forward from measured PPFD and lamp hours (with optional winter sunlight), or size fixtures backward from target DLI, canopy capture factor, and PPE.

Open calculator
Engineering schematic showing operating reservoir volume, pump-off drain-back reserve, separated A/B dosing, and EC25 sensor Drain-back space Operating vol Part A + B · EC25 18-22 °C · mL/L

Reservoir volume, Part A/B dosing & EC25 drift calculator

Compute separate Part A/B milliliters from bottle-label rates by actual water volume, convert EC25 ↔ 500/700 ppm, or run calibrated EC25 dosing and drift triage.

Open calculator
Engineering schematic pairing a centrifugal pump TDH Q-H operating point with submerged DWC air diffuser sizing Q-H curve vs TDH 0.15-0.25 L/min/L

Hydroponic pump TDH & DWC aeration calculator

Derive NFT pump flow from channel count or total flow, compute TDH for the pump Q-H curve, and size DWC aeration against submerged stone depth backpressure.

Open calculator

Diagnose a growing or climate failure

Separate competing root, EC25/pH, foliar, condensation, algae, and thermal-outage causes before adjusting inputs.

Browse all 100 diagnostic guides

Head-to-head system & glazing decisions

Measurable two-option comparisons with thermal U-values, airflow trade-offs, and hydraulic failure boundaries.

All 126 comparisons

Deep Water Culture (DWC) vs. Nutrient Film Technique (NFT)

Choose DWC for larger operating solution volume, stronger EC25 and temperature buffering, and deeper root zones, and choose NFT when lightweight tiered channels for shallow-rooted greens outweigh rapid root desiccation during pump failures.

Kratky vs. Deep Water Culture (DWC)

Choose Kratky for zero-power, single-fill leafy greens where avoiding electrical failure outweighs refill flexibility, and choose DWC when continuous aeration at 0.568-0.946 L/min per US gal (0.15-0.25 L/min per L) against depth backpressure is needed for longer-cycle or fruiting edible crops.

Deep Water Culture (DWC) vs. Dutch Bucket

Choose DWC for compact single-reservoir setups where solution temperatures remain cool enough for submerged oxygenation, and choose Dutch buckets when heavy vining crops need isolated drained root space, lower submerged volume, and modular top-fed return plumbing.

Polycarbonate vs. Tempered Glass for Backyard Greenhouses

Choose multiwall polycarbonate when winter heat retention, diffused light, and lighter framing matter most, and choose single-layer tempered glass when maximum direct light transmission, scratch resistance, and multi-decade optical clarity outweigh conductive heat loss.

6mm vs. 10mm Twin-Wall Polycarbonate Glazing

Choose 10 mm twin-wall polycarbonate on flat-planed winter-heated greenhouses for its 0.53 BTU/(h·ft²·°F) (3.0 W/(m²·K)) U-value and higher span stiffness, and choose 6 mm panels when cold-bending onto arched roofs or fitting shallow kit extrusions.

Stone Wool vs Coco Coir for Hydroponics

Choose stone wool for uniform blocks and low cation exchange. Before planting, saturate it with the nutrient solution specified for the product. Choose coco coir for reusable organic buffering after washing salts and supplying Ca/Mg.

Passive Ventilation vs. Powered Exhaust Fan for Small Greenhouses

Choose powered exhaust ventilation when calm summer heat, fine insect screening, or high static pressure stalls buoyancy-driven roof and side vents, and use passive ventilation when zero electrical draw and moderate outdoor breezes meet crop cooling targets.

Gable vs. Lean-To Greenhouse Design

Choose a freestanding gable greenhouse for full-day multi-directional sun exposure and cross-ventilation; choose an attached lean-to greenhouse to cut outdoor-exposed heat-loss surface area by excluding the shared building wall.

Complete specification library across 10 directories

Structured from hydroponic fluid architecture through greenhouse physics to crop profiles and differential troubleshooting.

1,519 guides

Hydroponic systems & water

Greenhouse climate, envelope & light

Media, edible crops & diagnosis