French Tarragon in a Seasonal Hobby Greenhouse

Allow French tarragon (Artemisia dracunculus var. sativa) in a seasonal hobby greenhouse up to 45 m² (~485 ft²) to enter natural winter dormancy in cool, barely damp coarse-media pots before flushing vigorous spring shoots under rising solar DLI, while keeping summer exhaust ventilation active to prevent damp-heat root decline.

For baseline crop biology, indoor year-round lighting, and non-seasonal hydroponic setups, see the parent French Tarragon growing guide. This guide covers the seasonal greenhouse cycle: winter chill management, dormant root moisture limits, spring solar shoot flush, and summer heat venting.

Boundary Conditions That Change the Setup

  • Winter chill window (35–45°F / 2–7°C): French tarragon is a temperate perennial that requires a cool rest period to reset crown vigor. If the greenhouse is heated above 55°F (13°C) through winter under low natural light, crowns push weak, low-flavor shoots and decline by the second year. Conversely, uninsulated container crowns exposed to hard freezes below 20°F (-7°C) risk freeze damage.
  • Coarse, fast-draining container media: Standard peat-heavy potting mixes stay saturated during cool winter weeks and cause rapid crown rot. Use coarse bark fines, perlite, pumice, or expanded clay pebbles that drain freely within seconds of irrigation.
  • Summer root-zone and air heat: Above 75°F (24°C) in the root zone, dissolved oxygen drops and Pythium root-rot risk rises sharply. Above 80–85°F (27–29°C) air temperature with stagnant humidity, foliage stalls and loses essential oil concentration.

Seasonal Target Specifications

Parameter Winter Dormancy Spring Shoot Flush Summer Production Autumn Hardening
Air temperature 35–45°F (2–7°C) 55–70°F (13–21°C) day / 45–55°F (7–13°C) night 65–78°F (18–26°C); vent at >=75°F (24°C) 45–60°F (7–16°C)
Root-zone temperature 35–45°F (2–7°C) 60–68°F (16–20°C) 65–72°F (18–22°C); keep <75°F (24°C) 45–60°F (7–16°C)
Target DLI Ambient 0–6 mol/m²/d (no supplemental light) 12–18 mol/m²/d (natural solar) 14–22 mol/m²/d (30–40% shade if >82°F / 28°C) 8–14 mol/m²/d (declining solar)
Nutrient EC25 0.0–0.4 mS/cm (plain water only) 1.0–1.4 mS/cm 1.2–1.6 mS/cm 0.4–0.8 mS/cm, tapering to 0.0
Solution / media pH 6.0–6.5 5.8–6.5 5.8–6.5 6.0–6.5
Irrigation state Barely damp; water only to prevent bone-dry desiccation Moderate; irrigate when top 1.5 in (38 mm) dries Frequent pulse irrigation; full drain-to-waste Reduced frequency as transpiration drops

Compatible Systems, Containers, and Spacing

  • Recommended systems: Top-drip or hand-watered 3–5 gal (11–19 L) nursery pots or Dutch buckets filled with coarse bark/perlite/pumice or expanded clay pebbles, elevated on open slatted benches. Open bench bottoms allow excess water to drain immediately and keep air circulating around the container walls.
  • Systems to avoid for seasonal crowns: Continuous standing-water Kratky or deep-water culture (DWC) reservoirs are poorly suited to seasonal greenhouse tarragon because dormant crowns cannot tolerate submerged or continuously wet roots during cold weather.
  • Spacing: Set pots at 14–18 in (350–450 mm) center-to-center. Tighter spacing traps humid air at the base of the stems and encourages foliar disease.
  • Propagation, pollination, and support: French tarragon does not produce viable seed; propagate only by spring crown division or softwood stem cuttings. No pollination is required. Formal trellising is unnecessary, though a 12–16 in (300–400 mm) perimeter twine ring or light stakes keeps tall 24–36 in (600–900 mm) spring stems upright and off adjacent pots.

Greenhouse Heating and Summer Ventilation Sizing

Size heating and exhaust equipment from the actual greenhouse envelope and fan static-pressure curves rather than rule-of-thumb guesses. The calculations below use an illustrative 10 ft x 12 ft (3.05 m x 3.66 m) hobby greenhouse with 120 ft² (11.1 m²) floor area, 8 ft (2.4 m) average height, 960 ft³ (27.2 m³) volume, 6 mm twin-wall polycarbonate glazing (U = 0.62 BTU/(hr·ft²·°F) or 3.5 W/(m²·K)), and 340 ft² (31.6 m²) of exposed surface area. Verify your actual surface area, glazing U-value, and air-change rate (ACH) before selecting equipment.

Winter Freeze-Protection Heating

In a seasonal tarragon house, heating only needs to hold a minimum of 35°F (2°C) during severe cold snaps to prevent hard crown freezes (<20°F / -7°C).

  • Conduction heat loss: Q_cond = U x A x delta_T
    • Illustrative example at 15°F (-9°C) outside and 35°F (2°C) inside (delta_T = 20°F or 11.1 K):
    • Q_cond = 0.62 x 340 x 20 = 4,216 BTU/h (3.5 x 31.6 x 11.1 = 1,228 W)
  • Air-infiltration sensible heat loss: Q_inf = 0.018 x V_ft3 x ACH x delta_T_F (metric: 0.335 x V_m3 x ACH x delta_T_K)
    • At 1.0 ACH: Q_inf = 0.018 x 960 x 1.0 x 20 = 346 BTU/h (0.335 x 27.2 x 1.0 x 11.1 = 101 W)
  • Total illustrative heat load: 4,216 + 346 = 4,562 BTU/h (1,329 W).
  • Circuit check: On a standard 120V/15A continuous circuit budget (1,440 W maximum continuous load), 1,329 W fits only if no other continuous loads (such as circulation fans or supplemental lights) run on the same circuit. Verify total continuous amp draw before connecting an electric heater.

Summer Exhaust Ventilation and Intake Sizing

  • Target summer airflow: Size exhaust ventilation for 1 air exchange per minute (60 ACH) to prevent heat buildup. For the illustrative 960 ft³ (27.2 m³) house, CFM_target = 960 CFM (1,631 m³/h).
  • Fan selection: Select the exhaust fan from the manufacturer's airflow-versus-static-pressure curve at 0.10–0.15 in w.g. (25–37 Pa) to account for intake louver and insect-screen resistance; never size from zero-static-pressure free-air ratings.
  • Net intake area: A_net = CFM_target / V_face. Using a maximum allowable intake face velocity of 400 ft/min (2.0 m/s):
    • A_net = 960 / 400 = 2.40 ft² (0.223 m²)
  • Gross intake frame area: Divide net area by the louver/screen free-area ratio from the hardware datasheet (using an illustrative 0.60 free-area ratio):
    • A_gross = 2.40 / 0.60 = 4.00 ft² (0.372 m²)

Nutrient Chemistry and Seasonal Workflow

Track seasonal nutrient strength using temperature-referenced EC25 (mS/cm) and dilute Part A and Part B concentrates separately into the reservoir. For meter scale conversions (500 NaCl vs. 700 442 ppm), automatic temperature compensation (ATC) rules, and baseline hydroponic mixing procedures, see the French Tarragon Hydroponic and Greenhouse Growing Profile.

Step-by-Step Seasonal Procedure

  1. Autumn cutback and dry-down: When daylength drops and lower leaves yellow, cut stems back to 2–3 in (50–75 mm) above the crown. Flush remaining fertilizer from the media with plain pH 6.0–6.5 water (EC25 <= 0.4 mS/cm) and let pots drain completely.
  2. Winter dormancy management: Keep daytime greenhouse vents cracked whenever sunny weather pushes interior air above 50°F (10°C) so crowns stay dormant at 35–45°F (2–7°C). Check pots every 10–14 days by weight and by probing 2 in (50 mm) into the media; apply a small volume of plain water only if the root ball is nearly dry.
  3. Spring division and shoot flush: When morning lows hold above 40°F (4°C) and natural solar DLI reaches 12 mol/m²/d (DLI = PPFD x hours x 0.0036), lift and divide crowded 2–3 year crowns if needed, repotting into fresh coarse media. Once new shoots reach 2–3 in (50–75 mm), resume fertigation at EC25 1.0–1.4 mS/cm and pH 5.8–6.5.
  4. Summer heat venting and harvest: Set the exhaust thermostat to engage at 75°F (24°C) and run continuous horizontal airflow fans across the bench canopy. If midday solar gain pushes leaf or pot temperatures above 82°F (28°C), deploy 30–40% exterior shade cloth and shade dark pot walls from direct sun. Harvest outer stems at 8–12 in (200–300 mm) to keep the crown open and productive.

Verification Checks

  • Media drainage check: After a full irrigation pulse, free water should stop dripping from pot bases within 2–3 minutes and leave no standing puddles on bench surfaces.
  • Root-zone temperature check: Probe the center of a sun-exposed pot at 3:00 PM on a clear summer afternoon; verify media temperature stays below 75°F (24°C).
  • Winter min/max check: Review a min/max thermometer weekly during winter to confirm air temperature stays between 25°F (-4°C) minimum and 55°F (13°C) maximum.
  • Ventilation and circuit check: Confirm intake louvers open fully when the exhaust fan starts, and verify total continuous heater + fan wattage stays within the 120V/15A (1,440 W) circuit limit.

Real Failure Modes

  • Damp-heat root decline (summer): Root-zone temperatures >=75°F (24°C) combined with over-watering lower dissolved oxygen and trigger Pythium root rot, causing sudden midday wilt even in wet media. Prevent by using coarse media, open slatted benches, pot wall shading, and active exhaust venting at 75°F (24°C).
  • Winter crown rot: Irrigating dormant pots on a fixed schedule at 35–45°F (2–7°C) keeps roots cold and anaerobic, turning crowns black and mushy before spring. Stop scheduled watering after autumn cutback and irrigate only when pots approach dry weight.
  • Premature winter flush: Heating the greenhouse above 55°F (13°C) during low-DLI winter months (<6 mol/m²/d) breaks dormancy early, producing pale, leggy growth that exhausts crown carbohydrate reserves. Vent sunny winter afternoons and heat only to prevent hard freezes.
  • Basal stem rot and lodging: Crowding pots closer than 12 in (300 mm) without horizontal airflow traps moisture around dense lower stems. Maintain 14–18 in (350–450 mm) spacing and harvest outer shoots regularly.