Exhaust Airflow Rate Sizing for Lean-To Greenhouses
Compute lean-to exhaust airflow from the mono-pitch trapezoidal air volume rather than a freestanding four-wall gable footprint, and scale the target air changes per minute (ACH/min) by the solar exposure of the three glazed sides. For hobby food-growing lean-to greenhouses up to 485 ft² (45 m²), baseline exhaust targets range from 0.50 to 1.50 ACH/min depending on orientation, exterior shading, and elevation.
← Target Exhaust Airflow Rates, ACH Conversions & Adjustments
Because an attached lean-to shares one opaque, insulated host wall, it receives no direct solar transmission through that wall. However, the mono-pitch roof concentrates warm air along the high ridge against the host wall, so sizing from eave height alone underestimates the volume that must be exchanged, while sizing from ridge height alone overestimates it.
Mono-Pitch Trapezoidal Volume Formula
Measure interior dimensions from the glazing surfaces to the host wall face. Do not use exterior roof flashing heights or nominal kit dimensions.
Cross-Sectional Area = W x ((H_eave + H_ridge) / 2)
Air Volume (V) = L x W x ((H_eave + H_ridge) / 2)
- L: Interior length along the shared host wall in ft (m)
- W: Interior projection from the host wall to the front eave in ft (m)
- H_eave: Interior height at the low front wall in ft (m)
- H_ridge: Interior height where the mono-pitch roof meets the host wall in ft (m)
For a lean-to with a knee wall, measure H_eave from the floor to the top of the front wall plate, because the lower knee wall encloses air volume that still exchanges heat with the plants and floor slab.
Orientation and Solar-Aperture Targets
The opaque host wall eliminates one full vertical solar aperture, shifting the peak heat load onto the remaining three glazed walls and the single sloped roof. Select the target ACH/min within the standard airflow rate sizing range based on which direction the glazed front wall faces:
| Lean-To Orientation | Solar Exposure Profile | Unshaded Target (ACH/min) | Exterior-Shaded Target (ACH/min) | Key Sizing Condition |
|---|---|---|---|---|
| South-facing (N. Hemisphere) | Peak midday and full-day direct solar gain on front wall and roof | 1.00–1.50 | 0.75–1.00 | Use upper end for single glazing or low thermal mass |
| West-facing | Intense afternoon sun coinciding with peak outdoor air temperature | 1.00–1.50 | 0.75–1.00 | Size for late-afternoon ambient + solar peak |
| East-facing | Morning solar gain when outdoor ambient air is cooler | 0.75–1.25 | 0.60–0.85 | Verify morning heat buildup if host wall blocks afternoon breeze |
| North-facing | Diffuse sky radiation; host wall blocks low-angle direct sun | 0.50–0.75 | 0.50 | Maintain at least 0.50 ACH/min for humidity and CO2 replenishment |
Shading Credits and Glazing Conditions
Only exterior shade cloth qualifies for the exterior-shaded ACH/min column; interior shade cloth traps absorbed solar heat inside the upper mono-pitch pocket and leaves the unshaded target in force. See Target Exhaust Airflow Rates, ACH Conversions & Adjustments for the full shading-credit rules and baseline ACH conversions.
- Glazing U-value effect: High-transmission single poly or single glass gains and loses heat rapidly, favoring the upper half of each unshaded ACH/min band; multi-wall polycarbonate (6–16 mm) diffuses light and moderates rapid spikes, though peak summer exhaust still requires at least 0.75–1.00 ACH/min on sun-exposed orientations.
Target CFM (m³/h) Sizing and Altitude Correction
Convert the mono-pitch volume and orientation-adjusted ACH/min into baseline volumetric airflow, then apply an air-density correction factor if the site sits above 2,000 ft (610 m).
Base Airflow (CFM) = V (ft³) x Target ACH/min
Base Airflow (m³/h) = V (m³) x Target ACH/min x 60
Design Airflow = Base Airflow x Altitude Factor
Because lower barometric pressure at elevation reduces air density and heat-removal capacity per unit volume, multiply Base Airflow by the elevation factor from Target Exhaust Airflow Rates, ACH Conversions & Adjustments rather than sizing from sea-level tables.
Step-by-Step Sizing Example (Illustrative)
Illustrative assumptions: A south-facing lean-to attached to a residential wall at 4,000 ft (1,220 m) elevation, unshaded, growing warm-season edible crops.
- Length (L): 16 ft (4.88 m)
- Projection (W): 10 ft (3.05 m) — footprint is 160 ft² (14.88 m²)
- Front eave height (H_eave): 6 ft (1.83 m)
- Host-wall ridge height (H_ridge): 10 ft (3.05 m)
- Calculate trapezoidal air volume:
- US:
16 ft x 10 ft x ((6 ft + 10 ft) / 2) = 1,280 ft³ - SI:
4.88 m x 3.05 m x ((1.83 m + 3.05 m) / 2) = 36.3 m³
- US:
- Select orientation-based ACH/min:
- South-facing, unshaded: select
1.00 ACH/minas the baseline target (increase toward1.25–1.50 ACH/minif summer outdoor highs regularly exceed crop tolerance or glazing is single-layer).
- South-facing, unshaded: select
- Compute base exhaust airflow:
- US:
1,280 ft³ x 1.00 ACH/min = 1,280 CFM - SI:
36.3 m³ x 1.00 ACH/min x 60 = 2,178 m³/h
- US:
- Apply altitude correction (4,000 ft / 1,220 m = 1.13):
- US:
1,280 CFM x 1.13 = 1,446 CFM - SI:
2,178 m³/h x 1.13 = 2,461 m³/h
- US:
- Select fan and size intake against static pressure:
- Check the fan manufacturer's Q-P (airflow vs. static pressure) curve at 0.10–0.15 in. w.g. (25–37 Pa) to account for exhaust shutters, insect screens, and intake louvers; never size from a zero-static-pressure free-air rating.
- Size net intake area from the design airflow divided by allowable face velocity, then divide by the louver/screen free-area ratio to find the gross intake frame area.
- Verify that the exhaust fan wattage plus any shared continuous loads (circulation fans, pumps, controllers) stays within 1,440 W on a dedicated 120V/15A continuous circuit budget.
Verification Checks
- Datasheet static-pressure check: Confirm the selected fan delivers at least the altitude-corrected CFM (m³/h) at 0.10–0.15 in. w.g. (25–37 Pa), not at 0.00 in. w.g.
- High-ridge placement check: Mount the exhaust fan on an end wall as close to
H_ridgealong the host wall as framing permits, with the intake louver on the opposite end wall near crop height, so air sweeps diagonally across the canopy and flushes the upper mono-pitch pocket. - Solar-noon delta-T check: Measure dry-bulb air temperature at shaded outdoor intake level and at upper canopy height under peak sun with the fan at full speed. A temperature rise greater than 5–10°F (3–6°C) indicates insufficient airflow, excessive intake restriction, or thermal short-circuiting.
Real Failure Modes
- Using eave height or gable formulas for volume: Plugging
H_eaveinto a rectangular volume formula omits the upper wedge along the host wall, under-sizing exhaust capacity where the hottest air accumulates. - Giving west-facing lean-tos a reduced "partial-sun" rate: Even though the east-side host wall blocks morning sun, late-afternoon solar radiation through west glazing stacks directly onto peak outdoor ambient temperatures, causing severe heat spikes if undersized.
- Taking an exhaust credit for interior shade cloth: Reducing CFM (m³/h) after hanging interior shade cloth traps superheated air against the mono-pitch roof, raising radiant and convective heat load on tall crops.
- Omitting altitude correction above 2,000 ft (610 m): Thin mountain air removes fewer BTU/h (W) per CFM (m³/h), leaving the greenhouse persistently warmer than outdoor air even when the fan runs continuously.
- Short-circuiting along the front eave: Placing the intake and exhaust both low on the front wall leaves a stagnant, overheated air layer trapped against the high host wall.