Day-to-Night Humidity Transitions & Sunset Moisture Purging for Hoop Tunnels
Purge warm, moisture-laden air through roll-up sidewalls or end-wall exhaust 30 to 45 minutes before sunset, then close and seal the baseboards before clear-sky radiative cooling drops the polyethylene film below the interior dew point and locks in saturated air.
← Day-to-Night Humidity Transitions & Sunset Moisture Purging
For general day-to-night psychrometric behavior across rigid-glazed structures, see Day-to-Night Humidity Transitions. Polyethylene hoop tunnels up to 45 m² (485 ft²) have very low thermal mass and high long-wave infrared transmittance (especially single-layer film), so their interior air and film temperatures track falling outdoor temperatures within minutes once direct solar gain ends.
Boundary Conditions That Change the Schedule
- Single-layer vs. air-inflated double polyethylene: Single polyethylene has an envelope U-value of 1.20 BTU/(h·ft²·°F) (6.8 W/(m²·K)) and transmits a large fraction of outgoing long-wave thermal radiation to the night sky. Double-layer inflated polyethylene drops the U-value to 0.70 BTU/(h·ft²·°F) (4.0 W/(m²·K)) and traps an insulating air gap, slowing film-surface cooling and giving a wider closing window.
- Clear sky vs. overcast dusk: On clear, calm evenings, radiative cooling drops the outer film temperature below ambient outdoor air temperature before astronomical sunset, causing condensation even when interior air still feels warm. Overcast skies reflect long-wave radiation back down, allowing purging closer to sunset.
- Outdoor air moisture content: Sunset purging only lowers interior absolute humidity if outdoor air has a lower dew point (lower actual vapor pressure) than the tunnel air. If outdoor air is already near saturation (fog, warm rain, or marine layer above 85% RH at similar temperature), prolonged purging brings in damp air without drying the canopy; limit the purge to a brief 5-minute thermal equalization and rely on horizontal airflow (HAF) plus supplemental heat after sealing.
- Crop transpiration load: Dense fruiting canopies late in the afternoon add moisture rapidly as stomata close. Start the purge slightly earlier (45 minutes before sunset) on high-transpiration days so solar warmth remains available to re-warm incoming air after closing.
Specifications and Sizing Reference
Pre-Sunset Purge & Closing Schedule
| Sky & Envelope Condition | Purge Start (Before Sunset) | Target Purge Duration | Post-Close Target |
|---|---|---|---|
Clear sky, single poly (U = 1.20 BTU/(h·ft²·°F) / 6.8 W/(m²·K)) |
40–45 min | 10–15 min | Seal before film reaches interior dew point; maintain VPD >= 0.4 kPa (<= 80% RH at 60°F / 15.6°C) |
Clear sky, double poly (U = 0.70 BTU/(h·ft²·°F) / 4.0 W/(m²·K)) |
30–35 min | 10–15 min | Seal while 5–8°F (2.8–4.4°C) solar residual heat remains; keep HAF running |
| Overcast sky, single or double poly | 20–30 min | 10–15 min | Seal before outdoor temp drops below 5°F (2.8°C) of target night minimum |
Rain or outdoor RH >= 85% |
15–20 min (brief swap only) | 5 min | Close early to trap dry daytime sensible heat; use HAF + thermostat heat to hold VPD |
Illustrative Hoop Tunnel Baseline (14 ft x 28 ft / 4.27 m x 8.53 m)
The following example uses an illustrative 14 ft x 28 ft (4.27 m x 8.53 m) hoop tunnel with a 392 ft² (36.4 m²) footprint, 8.5 ft (2.59 m) ridge height, 6.5 ft (1.98 m) average height, 2,548 ft³ (72.2 m³) air volume, and 720 ft² (66.9 m²) exposed polyethylene surface area. Verify actual film area, fan curves, and dimensions on your tunnel frame and equipment datasheets.
| Parameter | Unpurged Tunnel (Sealed Late) | Purged & Sealed Tunnel | Engineering Basis |
|---|---|---|---|
| Pre-sunset interior state (illustrative) | 75°F (23.9°C), 70% RH, ea = 2.07 kPa, VPD = 0.89 kPa |
75°F (23.9°C), 70% RH, ea = 2.07 kPa |
Dew point is 64.5°F (18.1°C) |
| Incoming outdoor purge air (illustrative) | Not exchanged | 62°F (16.7°C), 55% RH, ea = 1.04 kPa, VPD = 0.86 kPa |
Dew point is 45.7°F (7.6°C) |
Post-sunset state at 62°F (16.7°C) |
100% RH, VPD = 0.0 kPa (heavy film & leaf condensation) |
62°F (16.7°C), 55–65% RH, VPD = 0.66–0.86 kPa |
ea stays below es (1.90 kPa at 62°F) |
Target mechanical purge rate (0.5 air changes/min) |
0 CFM |
1,274 CFM (2,165 m³/h) for 10–15 min |
Airflow = Volume x 0.5 / min |
Intake net area (<= 400 ft/min / 2.03 m/s face velocity) |
N/A | 3.25 ft² (0.302 m²) net |
Net Area = 1,300 CFM / 400 ft/min |
Intake gross frame area (50% / 0.50 free-area ratio) |
N/A | 6.50 ft² (0.604 m²) gross |
Gross Area = Net Area / 0.50 (e.g., two 20 in x 24 in / 508 mm x 610 mm screened louvers) |
Single poly envelope heat loss (delta-T = 15°F / 8.3 K) |
12,960 BTU/h (3,790 W) |
12,960 BTU/h (3,790 W) |
Q_env = Area x U x delta-T |
Double poly envelope heat loss (delta-T = 15°F / 8.3 K) |
7,560 BTU/h (2,229 W) |
7,560 BTU/h (2,229 W) |
Q_env = Area x U x delta-T |
Infiltration loss at 0.5 ACH (sealed) vs 3.0 ACH (unsealed) |
2,064 BTU/h (604 W) at 3.0 ACH |
344 BTU/h (101 W) at 0.5 ACH |
Q_inf = 0.018 BTU/(h·ft³·°F) x Volume x ACH x delta-T (0.335 W/(m³·K) x V_m3 x ACH x delta-T_K) |
Governing Formulas (Plain Text)
- Vapor Pressure Deficit (VPD):
VPD = es(T_leaf) - ea(T_air, RH)in kPa, whereesis saturation vapor pressure andeais actual vapor pressure. - Purge Airflow (Exhaust Method):
CFM = Volume_ft3 x Air_Changes_Per_Min(m³/h = Volume_m3 x Air_Changes_Per_Min x 60). Verify fan output on the manufacturer static-pressure curve at0.05–0.10 in w.g.(12.5–25 Pa), not free-air zero-static ratings. - Intake Frame Sizing:
Net_Intake_Area = Target_Airflow / Allowable_Face_VelocityGross_Frame_Area = Net_Intake_Area / Free_Area_Ratio
- Envelope + Infiltration Heat Load:
Q_total (BTU/h) = (Area_ft2 x U_BTU x delta-T_F) + (0.018 x Volume_ft3 x ACH x delta-T_F)Q_total (W) = (Area_m2 x U_W x delta-T_K) + (0.335 x Volume_m3 x ACH x delta-T_K)
- Continuous Electrical Circuit Budget (120V/15A):
Existing_Continuous_Load_W + Heater_Input_W <= 1,440 W(80% continuous rating of1,800 VA).
Sunset Moisture Purging Procedure
- Check the interior-to-outdoor dew point spread (45 minutes before sunset).
Read interior dry-bulb temperature and RH, then compare against outdoor air. Confirm outdoor dew point is at least
5°F(2.8°C) lower than interior dew point before opening for a full purge. - Initiate the purge 30 to 45 minutes before sunset.
- Passive roll-up sidewalls: Roll both sidewalls up
12 to 18 in(305 to 457 mm)—or crack end-wall doors/vents if wind is strong—for10 to 15 minutesso gentle cross-breezes flush humid canopy air out without chilling soil or hydroponic reservoirs. - Mechanical end-wall exhaust: Open the opposing intake louvers/screens first, then run the exhaust fan at
0.5air changes per minute (1,274 CFM/2,165 m³/hin the2,548 ft³/72.2 m³baseline tunnel) for10 to 15 minutes. Keep intake face velocity at or below400 ft/min(2.03 m/s) so cold outdoor air mixes overhead before reaching plants.
- Passive roll-up sidewalls: Roll both sidewalls up
- Close and seal baseboards before the film cools to dew point.
Drop roll-up curtains fully into the baseboard batten or hip-board pocket and latch end-wall doors while
5 to 8°F(2.8 to 4.4°C) of solar warmth or daytime thermal mass remains. Leaving a0.5 in(13 mm) gap along a28 ft(8.53 m) baseboard raises nighttime infiltration from0.5 ACHtoward3.0 ACHand pulls cold, damp ground-level air across lower leaves. - Engage continuous horizontal airflow (HAF) after closing.
Run small HAF circulation fans continuously through the night to mix boundary-layer air around leaves and prevent stagnant pockets where local RH hits
100%against the cold poly skin. - Verify supplemental heater capacity on the circuit.
If nighttime
delta-Trequires electric heating to hold minimum leaf temperature and VPD (>= 0.4 kPa), add up all continuous loads on the120V/15Abranch circuit (HAF fans + controller + inflation blower + heater) and confirm the total does not exceed1,440 W. For example,90 Wof HAF fans plus a15 Wcontroller leaves1,335 W(4,555 BTU/h) maximum for an electric space heater on that circuit.
Verification Checks
- Post-close VPD check (30 minutes after sunset): Measure air temperature and RH at canopy height in the center of the tunnel. Confirm RH remains
<= 80%(VPD >= 0.4 kPaat60°F/15.6°C) and that the inner polyethylene surface is dry or shows only light, non-dripping mist. - Baseboard and door-sweep smoke/draft check: Walk the perimeter after closing; verify no cold drafts enter under the roll-up curtain or around end-wall framing.
- Intake louver & fan datasheet check: Confirm the exhaust fan delivers target CFM at
0.10 in w.g.(25 Pa) static pressure with insect screens installed, and verify screen + louver free-area ratio from the manufacturer datasheet rather than assuming100%open area. - Circuit load check: Sum nameplate watts of every continuous device on the
120V/15Acircuit and confirm<= 1,440 Wtotal.
Real Failure Modes and Fixes
- Closing at or after sunset: Waiting until dusk feels cool outside means the polyethylene film has already radiated heat to the sky and crossed the interior dew point. Fix: Move the closing trigger to
30–45 minutesbefore sunset on clear days, tied to a timer or solar-radiation threshold rather than outdoor air temperature alone. - Over-purging into cold twilight: Running exhaust fans or leaving sidewalls open for
30+ minutesstrips all stored heat from benches and floors, forcing the heater to work harder overnight and dropping leaf temperature into the condensation zone. Fix: Limit active purging to10–15 minutes(or5–7full air exchanges) and seal immediately. - Skipping HAF fans after sealing: Even in a properly purged tunnel, stagnant air in the
1 to 2 in(25 to 50 mm) boundary layer next to the polyethylene wall cools below dew point and drips onto perimeter crops. Fix: Keep low-wattage HAF circulation running all night. - Undersized or blocked intake louvers: Running an exhaust fan against a small or clogged insect screen drives static pressure above the fan curve stall point, cutting actual airflow in half and failing to purge moisture in time. Fix: Size gross intake frame area using the actual free-area ratio of the screen/louver assembly (
Net Area / Free-Area Ratio) and brush dust off screens weekly. - Tripping a 120V/15A circuit at night: Plugging a
1,500 Wspace heater into the same120V/15Acircuit already powering HAF fans and an inflation blower exceeds the1,440 Wcontinuous limit. Fix: Lock the heater to a lower wattage setting (<= 1,200 Wif fans draw100–200 W) or shed non-essential loads, and verify total continuous watts before cold nights arrive.