Cooling-Water Evaporation and Moisture Load Balance
Evaporative cooling converts sensible heat directly into water vapor, requiring continuous air exchange to export added moisture and periodic bleed-off to prevent mineral scaling. Each 10,000 BTU/h (2,931 W) of sensible cooling evaporates approximately 1.14 gal/h (4.32 L/h) of water into the airstream. Because that moisture stays in the air, evaporative pads or misting systems only lower air temperature when paired with single-pass exhaust ventilation (see Shading and Cooling) that removes humid exhaust air before vapor pressure deficit (VPD) collapses.
Boundary conditions that govern performance:
- Outdoor wet-bulb depression: Cooling potential equals dry-bulb temperature minus wet-bulb temperature, multiplied by pad saturation efficiency (typically 75–85% for clean corrugated cellulose pads). When outdoor relative humidity exceeds 75–80%, wet-bulb depression narrows to a few degrees, evaporative cooling drops sharply, and added moisture risks pushing greenhouse RH above 85%.
- Single-pass air exchange: Recirculating evaporatively cooled air inside a closed greenhouse raises absolute humidity until the air saturates and cooling stops. Exhaust airflow must match the pad intake airflow so moisture leaves continuously.
- Makeup water hardness: Pure water evaporates while dissolved minerals remain in the sump. Without continuous or timed bleed-off, sump electrical conductivity (EC25) climbs until calcium carbonate and magnesium salts precipitate onto the pad media, blocking airflow and reducing wetted surface area.
Core Governing Equations
All evaporative cooling calculations link sensible heat removal, water mass transfer, and exhaust air mass flow through the latent heat of vaporization of water (approximately 1,050 BTU/lb or 2,440 kJ/kg at 68–86°F / 20–30°C).
1. Evaporation Rate from Sensible Cooling Load
Imperial:
Evaporation (gal/h) = Sensible Cooling (BTU/h) / 8,760 BTU/gal
SI:
Evaporation (L/h) = Sensible Cooling (W) × 3.6 / 2,440 kJ/kg
= Sensible Cooling (kW) × 1.475 L/(h·kW)
2. Evaporation Rate from Airflow and Humidity Rise
When sizing from fan airflow and psychrometric state points (outdoor intake vs. pad-leaving air):
Imperial:
Evaporation (gal/h) = [Airflow (CFM) × 4.5 × (W_pad_out - W_outdoor)] / 8.345 lb/gal
SI:
Evaporation (L/h) = Airflow (m³/h) × 1.20 kg/m³ × (W_pad_out - W_outdoor)
Where W is the humidity ratio in lb water / lb dry air (or kg water / kg dry air), and 1.20 kg/m³ (4.5 lb/(h·CFM)) is standard air mass flow density at 68°F (20°C).
3. Pad-Leaving Air Temperature
T_pad_out = T_outdoor_DB - [Efficiency × (T_outdoor_DB - T_outdoor_WB)]
Where T_outdoor_DB is outdoor dry-bulb temperature, T_outdoor_WB is outdoor wet-bulb temperature, and Efficiency is 0.75–0.85 for properly wetted 4–6 in (100–150 mm) cellulose pads.
4. Mineral Bleed-Off and Total Makeup Water
To hold sump dissolved solids at a safe multiple of the supply water concentration (Cycles of Concentration, CoC = Target_Sump_EC25 / Makeup_EC25):
Bleed-Off (gal/h or L/h) = Evaporation / (CoC - 1)
Total Makeup (gal/h or L/h) = Evaporation + Bleed-Off
= Evaporation × [CoC / (CoC - 1)]
Reference Specifications and Operating Targets
| Parameter | Target / Design Range | Engineering Basis & Notes |
|---|---|---|
| Latent heat conversion | 1.14 gal/h per 10,000 BTU/h (1.48 L/h per kW) | Assumes 1,050 BTU/lb (2,440 kJ/kg) latent heat of vaporization |
| Cellulose pad saturation efficiency | 75–85% | Typical for 4–6 in (100–150 mm) corrugated pads at design face velocity |
| Minimum wet-bulb depression | >= 10°F (5.5°C) | Below this threshold, temperature drop is minor and exhaust RH approaches saturation |
| Target exhaust air RH | 60–75% (VPD 0.6–1.4 kPa) | Solar sensible heat gain across the canopy must warm pad-cooled air by 6–10°F (3.3–5.5°C) to keep foliage dry |
| Sump EC25 ceiling (hard water) | <= 2.0–2.5 mS/cm | Prevents calcium carbonate scaling on cellulose flutes; adjust CoC to stay below ceiling |
| Target Cycles of Concentration (CoC) | 2.0–4.0 | CoC 4.0 for soft water (<0.5 mS/cm); CoC 2.0 for hard water (>=1.0 mS/cm) |
| Sump volume reserve | >= 15–20% above drain-back volume | Must hold all water draining from pads, headers, and return troughs when pump stops |
Note on EC25 vs. TDS meters: Measure sump and makeup water concentration using temperature-referenced EC25 (mS/cm) as the primary metric. If using a handheld TDS meter, 500 (NaCl) and 700 (442) scales are meter conversion factors only—never treat them as a 40% salt difference or manually re-compensate readings from an automatic temperature compensation (ATC) meter.
Step-by-Step Sizing and Moisture Balance Procedure
Illustrative Example: A 215 ft² (20 m²) hobby food-growing greenhouse with a 1,766 ft³ (50 m³) air volume, shaded to limit net interior sensible solar heat load to 13,650 BTU/h (4,000 W). Outdoor design conditions are 95°F (35.0°C) dry-bulb and 30% RH, which corresponds to a 70.9°F (21.6°C) wet-bulb temperature (W_outdoor = 0.0105 kg/kg).
Determine pad-leaving air temperature and moisture gain:
- Using an 80% pad saturation efficiency:
T_pad_out = 95°F - 0.80 × (95°F - 70.9°F) = 75.7°F(24.3°C). - Pad moisture addition raises the humidity ratio by
0.0045 kg/kgtoW_pad_out = 0.0150 kg/kg, yielding 78.7% RH (0.65 kPaVPD) immediately downstream of the pad.
- Using an 80% pad saturation efficiency:
Size exhaust airflow to absorb interior sensible heat without over-humidifying:
- Allow an 8.3°F (4.6°C) temperature rise from the pad face to the exhaust fan so exhaust air exits at 84.0°F (28.9°C).
- Required mass airflow:
4.0 kW / (1.006 kJ/(kg·K) × 4.6 K) = 0.864 kg/s(3,110 kg/h), which equals1,552 CFM(2,636 m³/hat 1.18 kg/m³). - Verify on the exhaust fan static-pressure curve that the fan delivers
1,552 CFM(2,636 m³/h) against total system static pressure (pad pressure drop + louver/screen losses).
Calculate hourly pad evaporation rate:
- From airflow and humidity rise:
2,636 m³/h × 1.18 kg/m³ × 0.0045 kg/kg = 14.0 L/h(3.70 gal/h). - Cross-check from pad sensible cooling power:
3,110 kg/h × 1.006 kJ/(kg·K) × 10.7 K / 3,600 = 9.30 kW(31,730 BTU/h). Dividing by8,760 BTU/galgives3.62 gal/h(13.7 L/h)—confirming energy and mass balance alignment.
- From airflow and humidity rise:
Account for crop transpiration and verify exhaust VPD:
- Active edible crops across 215 ft² (20 m²) add roughly
0.40–0.80 gal/h(1.5–3.0 L/h) of transpired moisture depending on canopy density, raising exhaust humidity ratio by0.0006–0.0011 kg/kg. - Because the air warms from 75.7°F (24.3°C) at the pad to 84.0°F (28.9°C) at the exhaust, exhaust RH drops from 78.7% at the pad to roughly 63–65% (
~1.4 kPaVPD), keeping foliage dry and transpiration active.
- Active edible crops across 215 ft² (20 m²) add roughly
Calculate mineral bleed-off and total water supply:
- Assume local makeup water measures
0.50 mS/cmEC25 and the sump ceiling is set to2.00 mS/cm(CoC = 2.00 / 0.50 = 4.0). Bleed-Off = 3.70 gal/h / (4.0 - 1) = 1.23 gal/h(4.67 L/h).Total Makeup = 3.70 + 1.23 = 4.93 gal/h(18.67 L/h).
- Assume local makeup water measures
Mineral Bleed-Off and Sump Water Management
- Continuous vs. timed bleed-off: Install a small adjustable bleed tee on the pump discharge header feeding a drain or non-edible landscape line. For small hobby sumps under 15 gal (57 L), a continuous trickle calibrated to the calculated bleed-off rate prevents sharp EC spikes. Alternatively, drain and refill the sump completely after the calculated operating hours before EC25 exceeds
2.0–2.5 mS/cm. - Float valve placement: Mount the makeup float valve so it maintains the operating water level at least 2–3 in (50–75 mm) below the sump overflow port during pump-on operation.
- Drain-back allowance: Measure the internal volume of the supply riser, distribution header, wet pad hold-up, and return gutter. Verify the sump freeboard above the pump-on operating line exceeds that total drain-back volume so power outages or thermostat shutoffs do not flood the greenhouse floor.
- Algae and biofilm control: Keep the sump covered with an opaque lid to block light and prevent algae growth on the pump intake screen. Allow the pad pump to shut off 30–60 minutes before sunset while keeping the exhaust fan running for 10–15 minutes to dry the pad surface daily, suppressing biofilm buildup.
Verification Checks
- Pad temperature drop test: Measure dry-bulb temperature 12 in (300 mm) outside the pad and 12 in (300 mm) inside the pad face during peak afternoon heat. Confirmed drop should reach 75–85% of outdoor wet-bulb depression; a lower drop indicates dry pad streaks, clogged flutes, or excessive intake air velocity.
- Exhaust VPD and foliage check: Measure temperature and RH near the exhaust end of the plant canopy. Exhaust RH should remain below 75–80% with no visible condensation on leaf margins or glazing.
- Sump EC25 drift check: Test sump water with a calibrated ATC EC25 meter after three days of peak operation. If EC25 climbs above
2.0–2.5 mS/cm, increase the bleed-off valve rate or shorten the sump dump-and-refill interval. - Pump-off drain-back test: Fill the sump to its normal pump-on operating mark, run the system for 5 minutes to saturate the pads, then cut power to the circulation pump. Confirm all draining water stays below the sump rim and overflow fitting.
Real Failure Modes
- VPD collapse and foliar disease from poor air exchange: Running evaporative pads or misting nozzles with exhaust fans turned off or intake louvers blocked traps water vapor inside the greenhouse. Relative humidity climbs past 90%, evaporative cooling stalls, and free moisture condenses on leaves overnight when temperatures dip.
- Calcium carbonate scaling on pads: Skipping bleed-off with hard makeup water concentrates bicarbonates and calcium until white mineral crust bridges the cellulose flutes. Scaled pads restrict intake airflow, force the exhaust fan higher up its static-pressure curve, and drop cooling efficiency below 50%.
- Hot-air bypass through dry pad streaks: Clogged header distribution holes or insufficient pump flow at total dynamic head leave vertical dry strips in the pad. Outside air at 95°F (35°C) pulls straight through the dry gaps, creating hot spots across the crop canopy.
- Sump overflow on pump shutoff: Sizing the sump solely for pump-on submergence without reserving drain-back freeboard causes the sump to overflow every time the thermostat cycles the pump off, wasting water and raising floor humidity.