Cumulative Dose Limits and Overdose Lockout Thresholds

Cap both single-shot runtime (mL per event) and rolling 24-hour cumulative volume (mL per 24 h) independently for every dosing channel—Part A, Part B, and pH adjuster—and enforce a mandatory mixing deadtime between shots. A single-shot cap bounds the chemical shift of any one command, while a rolling 24-hour cumulative cap stops slow, repeated overdosing caused by probe drift, reservoir leaks, or stuck-open control loops within Dosing Automation.

Boundary conditions that shift these limits:

  • Operating reservoir volume (V_op): Base all dose caps on the active operating volume while circulation pumps are running, excluding pump-off drain-back capacity. Smaller operating volumes experience larger EC25 (mS/cm) and pH swings per mL of concentrate.
  • Actual pump delivery rate (Q_pump): Peristaltic pump output varies with tubing age, squeeze-tube ID, and check-valve cracking pressure. Always derive runtime limits from a measured mL/s calibration, not nominal nameplate ratings.
  • Concentrate strength and source water alkalinity: Higher-concentration stock solutions (for example, 1:200 vs. 1:100) require tighter mL caps. High-alkalinity source water with continuous fresh-water top-off consumes more pH-down per 24 hours than a closed batch.
  • Crop transpiration stage: Peak-canopy fruiting crops transpire substantially more water and nutrients per day than seedlings, shifting the normal 24-hour baseline demand.

Lockout Layer Specifications

Each dosing channel requires four independent software/firmware limits plus a physical or hardware-level runtime backstop.

Lockout Parameter Sizing Basis Failure Mode Caught What to Verify on Hardware/Datasheet
Single-Shot Volume Cap (V_shot_max) Small fraction of a target correction in V_op (typically bounding a single pulse to <= 0.05–0.10 mS/cm EC25 or <= 0.1–0.2 pH units) Sensor spike, transient electrical noise, or single-command software glitch Minimum reliable on-time of the pump and controller relay resolution (s)
Max Single-Shot Runtime (t_shot_max) t_shot_max = V_shot_max / Q_pump Controller hang or missed stop command Hardware watchdog or relay timer limit independent of main PID loop
Inter-Dose Mixing Deadtime (t_mix) Time for at least 1–2 full reservoir turnovers past the sensor manifold Re-dosing before concentrate fully mixes into V_op Circulation pump flow rate at actual head and sensor manifold lag
Rolling 24-Hour Cumulative Cap (V_24h_max) 1.25–1.50 x measured normal daily channel demand (V_daily_base) Probe calibration drift, disconnected probe, or reservoir leak with auto-top-off Whether the 24-hour accumulator uses a true sliding window and persists across power loss
Consecutive-Dose Fault Limit (N_max) Maximum back-to-back shots allowed without measurable EC25 or pH movement (typically 3–5 shots) Split tubing, empty stock bottle, air-locked line, or fouled probe Controller support for rate-of-change / no-response fault latching

Plain-Text Sizing Equations

Calculate runtime and cumulative caps from measured system values in SI units (convert US gal to L using L = gal x 3.78541):

t_shot_max (s) = V_shot_max (mL) / Q_pump (mL/s)

V_24h_max (mL) = V_daily_base (mL/day) x Safety_Factor (1.25 to 1.50)

t_mix (min) >= (V_op (L) / Q_circ (L/min)) x 2

Illustrative Sizing Example (50 gal / 189.3 L Reservoir)

Illustrative assumptions (verify against your own stock bottle label, pump calibration, and reservoir drawdown):

  • Operating reservoir volume: V_op = 50 US gal (189.3 L)
  • Circulation pump turnover: 10 gal/min (37.9 L/min) -> 1 turnover = 5.0 min
  • Measured peristaltic pump flow: Q_pump = 60 mL/min (1.0 mL/s) per channel
  • Stock concentrate ratio: 1:100 Part A + 1:100 Part B (dosed separately), where 10 mL of Part A + 10 mL of Part B in 189.3 L raises EC25 by roughly 0.05 mS/cm
  • Measured baseline daily nutrient demand: V_daily_base = 120 mL/day per A/B channel

Derived Lockout Settings per A/B Channel:

  1. Single-Shot Volume Cap (V_shot_max): 10 mL (bounds one event to ~0.05 mS/cm total when paired with the matching channel).
  2. Max Single-Shot Runtime (t_shot_max): 10 mL / 1.0 mL/s = 10 s.
  3. Mixing Deadtime (t_mix): 5.0 min x 2 = 10 min minimum wait before the next command on that channel; stagger Part B at least 2–5 min after Part A so concentrates never meet undiluted.
  4. Rolling 24-Hour Cumulative Cap (V_24h_max): 120 mL/day x 1.35 = 162 mL per 24-hour rolling window.
  5. Consecutive-Dose Fault Limit (N_max): 4 consecutive shots (40 mL) without at least a 0.05 mS/cm EC25 rise triggers a hard lockout.

Configuration Steps

  1. Measure true operating volume (V_op): Run all circulation and irrigation pumps until return lines stabilize, then measure the water depth and cross-sectional area of the sump/reservoir. Do not include the empty headspace reserved for pump-off drain-back.
  2. Calibrate every pump channel (Q_pump): Place each dosing line's discharge end at its actual injection elevation (with check valves installed) and pump water into a graduated cylinder for 30 s or 60 s. Divide measured mL by seconds to get Q_pump (mL/s).
  3. Separate and stagger Part A and Part B: Assign distinct channels, injection points, and timers to Part A and Part B. Never permit simultaneous dosing; require full mixing dispersion between Part A and Part B pulses to prevent localized salt precipitation.
  4. Log 3–7 days of baseline consumption (V_daily_base): Before enabling tight automatic lockouts, record normal daily mL consumption for each channel across stable solution temperatures (65–72°F / 18–22°C) and normal pH (5.5–6.5). Set V_24h_max to 1.25–1.50 x that observed daily demand.
  5. Enable latching lockout behavior: Configure both t_shot_max violations and V_24h_max trips to latch off (disable all dosing relays and raise an alert) until manually inspected and cleared. Do not use auto-resetting timers on cumulative overdose faults.

Verification Checks

  • Graduated-cylinder catch test: Divert the dosing outlet into a graduated cylinder and trigger a manual or simulated demand. Verify that the controller cuts power at t_shot_max and that delivered volume matches V_shot_max within ±5%.
  • 24-hour accumulator trip test: Temporarily lower V_24h_max (for example, to 2 x V_shot_max), trigger consecutive pulses after t_mix expires, and confirm the channel locks out immediately upon reaching the threshold and stays locked until manually cleared.
  • Power-loss persistence test: Accumulate partial 24-hour dose volume, cycle power to the controller, and verify whether the rolling 24-hour total is retained in non-volatile memory. If it resets to zero on reboot, add an external hardware timer or reduce V_24h_max to account for brownout risk.
  • ATC and probe sanity check: Confirm the EC25 meter/controller uses automatic temperature compensation (do not apply manual temperature offsets on top of an ATC reading) and verify pH/EC25 buffer calibration before relying on automated lockouts.

Real Failure Modes

  • Reservoir leak with auto-top-off (ATO): A slow fitting leak causes fresh water to dilute the reservoir continuously. EC25 drops, and the controller doses Part A and Part B repeatedly to hold setpoint. Without a rolling 24-hour cap, the system dumps excessive nutrients into a shrinking or leaking loop.
  • Probe dry-out or biofouling: If an inline EC25 probe traps an air bubble or a pH probe coats with biofilm, readings lag or stick artificially low/high. Single-shot caps limit each pulse, while the consecutive-dose fault counter (N_max) and V_24h_max halt dosing before pH crashes below 5.5 or EC25 spikes into root-burn territory.
  • Concentrate precipitation from simultaneous dosing: Triggering Part A and Part B at the same time—or without adequate t_mix—creates high localized concentration in the sump, precipitating insoluble calcium sulfate or calcium phosphate and throwing off the N-P-K/Ca balance even though total mL stayed within budget.
  • Rolling-window reset on power brownout: Controllers that store the 24-hour dose total only in volatile RAM reset to 0 mL after a brief power flicker, allowing another full 24-hour dose allowance immediately after reboot.
  • Worn squeeze tube or failed check valve: A fatigued peristaltic tube delivers far less than Q_pump, or a leaking check valve allows stock concentrate to siphon into the reservoir (or reservoir water to back-siphon into the stock bottle), decoupling controller runtime logs from actual chemical mass added.