Calculating Total Dynamic Head for Ebb-and-Flow Flood Pumps

Open calculator ↓

Enter 0 psi (0 kPa / 0 ft / 0 m) for terminal pressure and set static head to the peak vertical elevation difference between the drawn-down reservoir water surface and the flood tray standpipe overflow crest in the shared total dynamic head calculation calculator. Sizing against this worst-case peak-fill head on the pump's Q-H curve ensures the pump still delivers enough flow to reach the standpipe within your target fill window at maximum flood depth.

Hydroponic pump TDH & DWC aeration calculator

Determine pump total dynamic head from static lift, true pipe inner diameter, fittings, and emitters for Q-H curves, or size DWC aeration at depth backpressure.

Pump circuit, true pipe ID & total dynamic head

Open lift adds reservoir-surface-to-discharge height; closed full-pipe recirculation has 0 static lift. Use true pipe inner diameter, not nominal pipe size, and match (flow, TDH) on the pump Q-H curve.

Boundary conditions that change this setup:

  • Over-rim top-fill discharge: If the supply line discharges openly above the tray rim rather than through a bottom bulkhead, set static head to the vertical distance from the drawn-down reservoir surface to the open pipe outlet.
  • Multi-tray parallel manifolds: Set static head to the highest standpipe crest on the manifold, and sum the net flood volumes of all simultaneously flooded trays to compute total reservoir drawdown.
  • Submerged vs. external inline pumps: Measure static head from the water surface in the reservoir—not from the pump housing—because the surrounding reservoir water column balances the depth of a submerged pump.

Ebb-and-Flow TDH Components and Specifications

In the shared L1 pump calculator, total dynamic head is the sum of static elevation, pipe friction, fitting losses, and terminal pressure:

TDH = H_static + H_friction + H_fittings + H_terminal

TDH Component Ebb-and-Flow Value / Definition Why It Applies Common Mistake to Avoid
Static Head (H_static) Z_crest - (Z_res_idle - Delta_h) At peak flood, water in the tray presses down on the bottom bulkhead with head equal to the tray depth, while the reservoir surface drops by Delta_h. Measuring to the tray floor or from the idle (full) reservoir surface.
Pipe Friction (H_friction) Head loss per 100 ft (30.5 m) at target flow using true pipe ID Smooth vinyl tubing, Schedule 40 PVC, and barbed fittings have different internal diameters for the same nominal size. Using nominal pipe size (e.g., 3/4 in nominal instead of 0.824 in / 20.9 mm Sch 40 ID or 0.750 in / 19.1 mm tubing ID).
Fitting Losses (H_fittings) Sum of K * v^2 / (2 * g) or equivalent pipe lengths for elbows, tees, and bulkheads Barbed 90° elbows and abrupt bulkhead transitions add concentrated turbulence loss. Omitting barbed insert restrictions, which have smaller IDs than the tubing they join.
Terminal Pressure (H_terminal) 0 ft (0 m) / 0 psi (0 kPa) Flood bulkheads discharge openly into the tray at atmospheric pressure without nozzles or drip emitters. Entering drip-emitter pressure (10–25 psi / 69–172 kPa), which grossly oversizes the pump.

Illustrative Sizing Example (4 ft × 4 ft Flood Table)

The following example uses illustrative assumptions for a single indoor flood table; verify actual tray dimensions, media void fraction, reservoir footprint, and tubing ID on your hardware before ordering a pump.

Assumed system parameters:

  • Flood tray interior: 4 ft × 4 ft (1.22 m × 1.22 m), area A_tray = 16 ft² (1.49 m²)
  • Standpipe overflow crest height above tray floor: 5 in (127 mm)
  • Media: coarse expanded clay pebbles with an assumed void fraction of 0.50 (verify with a bucket displacement test on the specific batch)
  • Tray floor elevation above idle reservoir water surface: 28 in (711 mm)
  • Reservoir footprint: 24 in × 36 in (610 mm × 914 mm), area A_res = 6.0 ft² (0.557 m²)
  • Target fill window: 10 min (600 s)
  • Plumbing: 10 ft (3.05 m) of 3/4 in (19.1 mm true ID) flexible vinyl tubing with two 90° barbed elbows and one tray bulkhead

Derived values:

  1. Gross flood volume to crest: 16 ft² × (5 / 12) ft = 6.67 ft³ (49.9 US gal / 188.8 L)
  2. Net flood volume (V_flood at 0.50 void fraction): 49.9 US gal × 0.50 = 25.0 US gal (94.6 L / 3.34 ft³)
  3. Reservoir drawdown (Delta_h): 3.34 ft³ / 6.0 ft² = 0.557 ft = 6.7 in (170 mm)
  4. Peak static head (H_static): 28 in + 5 in + 6.7 in = 39.7 in = 3.31 ft (1.01 m)
  5. Required average fill flow (Q_avg): 25.0 US gal / 10 min = 2.5 GPM (150 GPH / 9.46 L/min / 0.568 m³/h)
  6. Fluid velocity in 3/4 in (19.1 mm) ID tubing at 3.0 GPM (11.4 L/min): 2.2 ft/s (0.67 m/s), keeping friction and fitting losses low (typically under 0.5 ft / 0.15 m for a short run; verify exact K-values in the calculator).
  7. Peak-fill TDH: ~3.8 ft (1.16 m). Select a pump whose Q-H curve delivers at least 2.5–3.0 GPM (150–180 GPH / 9.5–11.4 L/min) at 3.8 ft (1.16 m) of head—never select from a 0 ft (0 m) shutoff/open-flow rating.

Step-by-Step Calculation Workflow

  1. Separate operating volume from drain-back volume. Determine the net water volume needed to fill the tray to the standpipe crest (V_flood = A_tray × H_crest × void_fraction). Confirm the reservoir holds V_flood above the minimum pump submergence level while leaving freeboard below the reservoir rim for complete pump-off drain-back.
  2. Compute reservoir drawdown (Delta_h). Divide V_flood by the reservoir's horizontal cross-sectional area at operating depth (Delta_h = V_flood / A_res). For tapered tubs, use the narrower lower-half area to avoid underestimating drawdown.
  3. Measure peak static head (H_static). Measure vertically from the idle reservoir water surface to the top edge of the standpipe overflow crest, then add Delta_h. Enter this total as static head in the L1 calculator.
  4. Set terminal pressure to zero and enter true pipe ID. Set H_terminal = 0. Measure the actual inner diameter of your tubing or Schedule 40/80 PVC and count all elbows, tees, and bulkhead fittings. Keep pipe velocity below 5 ft/s (1.5 m/s) so friction loss does not dominate a low-head flood pump.
  5. Check the manufacturer Q-H curve at peak TDH. Verify that the pump's flow rate at peak TDH meets or exceeds V_flood / t_fill. Because flow is faster at the start of the cycle (lower static head) and slows as the tray approaches the standpipe, matching Q_avg at peak TDH provides a built-in margin for the target fill window.

Verification Checks After Installation

  • Timed peak-fill check: Run a flood cycle from the normal operating reservoir level and time how long it takes for water to first spill over the standpipe crest. Confirm the elapsed time is within your target fill window (t_fill).
  • Peak-drawdown pump submergence check: At the moment water reaches the standpipe crest, inspect the reservoir. The pump intake must remain fully submerged with enough depth above it to prevent air-entraining vortices.
  • Pump-off drain-back check: Shut off the pump and wait for the tray to drain completely back through the pump into the reservoir. Verify the reservoir water level stops safely below the overflow/rim without spilling.

Real Failure Modes

  • Check valve installed on a single-pipe flood/drain line: Standard ebb-and-flow tables drain back down the supply pipe through the pump impeller when the timer turns off. Adding a check valve traps water in the tray, keeping roots submerged and causing oxygen starvation.
  • Pump stalls just below the standpipe crest: Underestimating H_static by ignoring tray flood depth (H_crest) and reservoir drawdown (Delta_h) places the operating point near the pump's shutoff head. Water rises partway up the media and never triggers overflow circulation.
  • Air-locking or vortexing at peak flood: If Delta_h drops the reservoir surface to the pump intake before the tray reaches the standpipe, the pump ingests air, loses prime, and runs dry.
  • Excessive restriction from barbed fittings and undersized tubing: Using 1/2 in (12.7 mm) nominal tubing with multiple 3/8 in (9.5 mm) ID barbed elbows drives velocity above 5 ft/s (1.5 m/s), turning a short run into several feet of avoidable friction head.