Hoop-Tunnel Envelope Conduction Heat Loss Calculation

Open calculator ↓

Calculate steady-state hoop-tunnel conduction heat loss from the exposed above-grade curved arch surface area, the two semi-elliptical end-wall areas, and the steady-state film U-value—1.20 BTU/(h·ft²·°F) (6.8 W/(m²·K)) for single-layer polyethylene or 0.70 BTU/(h·ft²·°F) (4.0 W/(m²·K)) for double-layer inflated polyethylene—without applying separate wind multipliers:

Cross-section of an arched hoop tunnel greenhouse anchored with ground stakes and lower side roll-up ventilation curtainHOOP TUNNEL & GROUND ANCHORS Arch span He = 0 / sidewall Ground stakes Roll-up venting Curved roof sheds snow; verify film tension & anchors

Greenhouse heating load & circuit budget calculator

Size winter greenhouse heat loss from exposed glazing U-values (excluding insulated lean-to walls) plus ACH air infiltration, and verify total branch-circuit load.

Greenhouse geometry & exposed glazing

Lean-to excludes the shared insulated back wall. Hoop uses semi-elliptical/semicircular arch geometry (set eave height = 0 for ground-sprung tunnels). Glazing: 4–10 mm 2W PC = twin-wall, 16 mm 3W PC = triple-wall, double air poly = air-inflated double film; U shown as W/m²K / BTU/(h·ft²·°F). Hobby scope ≤ 45 m² (~485 ft²).

Design temperatures & air infiltration (ACH)

Air infiltration (ACH) captures air leakage and wind exposure directly—do not stack an extra wind multiplier on top.

Known branch-circuit continuous load check

Include all continuous devices sharing the same breaker. Default assumes a known 120V/15A continuous 80% budget (1,440 W) in EN or a conservative dedicated 230V/16A budget assumption (2,800 W) in DE/FR.

Q_cond = (U_arch * A_arch + U_end * 2 * A_end) * delta_T

For hoop tunnels up to 485 ft² (45 m²) of floor area, this conduction term belongs to the overall Envelope Conduction Heat Loss framework. Keep calculations aligned to SI units internally (W/(m²·K), m², K) and convert final heating capacity using 1 W = 3.412 BTU/h.

Boundary Conditions That Change the Answer

  • Arch arc length vs. floor width: Heat conducts through the curved overhead film (S_arc * L), not the ground footprint (W * L). Using footprint area underestimates roof/sidewall conduction by roughly 35%–45%.
  • Double-layer inflation state: The 0.70 BTU/(h·ft²·°F) (4.0 W/(m²·K)) rating applies only while a continuous inflation blower maintains an air gap between the inner and outer films. If the blower fails or a tear lets the layers touch, conduction reverts to single-layer 1.20 BTU/(h·ft²·°F) (6.8 W/(m²·K)), raising conductive heat loss by 70%.
  • No wind multipliers on U-value: Published U-values already include standard exterior convective film resistance. Account for wind-driven air leakage separately in the air-infiltration sensible heat term (0.018 BTU/(h·ft³·°F) or 0.335 W/(m³·K) * volume * ACH * delta_T) rather than multiplying Q_cond by a wind factor.
  • Ground-contact skirt boundary: Exclude the interior soil or gravel floor from A_total in air-to-air conduction, but measure S_arc all the way down to the ground-contact skirt or baseboard where exterior air contacts the wall.
  • Mixed end-wall glazing: If end walls use rigid twin-wall polycarbonate instead of polyethylene film, calculate 2 * A_end using the polycarbonate U-value and sum U * A terms before multiplying by delta_T.

Polyethylene and End-Wall Glazing U-Values

Envelope Assembly Imperial U-Value Metric U-Value (SI) Required Condition
Single-layer polyethylene film 1.20 BTU/(h·ft²·°F) 6.8 W/(m²·K) Tightly tensioned single film
Double-layer inflated polyethylene 0.70 BTU/(h·ft²·°F) 4.0 W/(m²·K) Active blower maintaining separated air gap
4 mm (0.16 in) twin-wall polycarbonate (end wall) 0.69 BTU/(h·ft²·°F) 3.9 W/(m²·K) Sealed flutes at top and bottom
6 mm (0.24 in) twin-wall polycarbonate (end wall) 0.62 BTU/(h·ft²·°F) 3.5 W/(m²·K) Sealed flutes at top and bottom
8 mm (0.31 in) twin-wall polycarbonate (end wall) 0.58 BTU/(h·ft²·°F) 3.3 W/(m²·K) Sealed flutes at top and bottom
10 mm (0.39 in) twin-wall polycarbonate (end wall) 0.53 BTU/(h·ft²·°F) 3.0 W/(m²·K) Sealed flutes at top and bottom

Verify the exact glazing thickness and manufacturer U-value on product datasheets if your end walls use multi-wall panels or thermal-barrier films.


Measuring Arch Arc Length, End-Wall Area, and Skirt Boundaries

1. Continuous Arch Arc Length (S_arc) and Roof/Wall Area (A_arch)

For an existing hoop tunnel, pull a flexible tape measure directly over the exterior of a central hoop from the ground-contact skirt on one side, over the ridge, to the ground-contact skirt on the opposite side. Direct measurement captures custom bends, swaged joints, and Gothic peak profiles without geometric error.

When estimating before assembly, use the profile equations below (W = span width, H = ridge height, L = tunnel length):

  • Semicircular hoop (H = W / 2):
    S_arc = pi * (W / 2)
    A_arch = S_arc * L
    
  • Semi-elliptical hoop (H != W / 2, no vertical knee walls): Let a = W / 2 and b = H. Using Ramanujan's half-ellipse perimeter:
    S_arc = (pi / 2) * (3 * (a + b) - sqrt((3 * a + b) * (a + 3 * b)))
    A_arch = S_arc * L
    
  • Hoop with vertical knee walls (h_wall on each side): Measure or calculate the curved upper arch S_upper above the knee-wall hip, then add both vertical walls:
    S_arc = 2 * h_wall + S_upper
    A_arch = S_arc * L
    

2. End-Wall Area (A_end)

For both front and rear end walls combined (2 * A_end):

  • Semicircular end wall:
    A_end = (pi / 8) * W^2
    2 * A_end = (pi / 4) * W^2
    
  • Semi-elliptical end wall:
    A_end = (pi / 4) * W * H
    2 * A_end = (pi / 2) * W * H
    
  • Knee-wall + semi-elliptical arch end wall:
    A_end = (W * h_wall) + (pi / 4) * W * (H - h_wall)
    

Do not subtract door framing from A_end unless the door is an insulated opaque panel with a known lower U-value; standard poly-skinned or polycarbonate-skinned doors conduct heat at roughly the same rate as the surrounding end wall.

3. Ground-Contact Skirt Boundaries

Skirt Construction How to Treat in Q_cond Notes
Buried polyethylene trench skirt Measure S_arc to soil grade Exclude buried underground film; include all film exposed to outdoor air
Single-layer wiggle-wire baseboard (<= 1 ft / 300 mm wood) Keep full S_arc at film U-value Uninsulated dimensional lumber (~1.5 in / 38 mm) does not materially lower total tunnel loss
Insulated perimeter knee wall (R-5+ foam-backed) Split knee-wall area out of A_arch Assign the insulated wall U-value (U = 1 / R_SI) to 2 * h_wall * L and film U-value to S_upper * L

Step-by-Step Calculation (Illustrative Example)

Illustrative assumptions: A backyard semi-elliptical hoop tunnel measuring 14 ft wide (4.267 m), 24 ft long (7.315 m), with a 336 ft² (31.2 m²) footprint and an 8.5 ft (2.591 m) ridge height. Design temperatures are 50°F (10.0°C) inside and 20°F (-6.7°C) outside, giving delta_T = 30°F (16.67 K). Both the arch and end walls are covered in polyethylene film.

Step 1: Compute the Arch Arc Length and Arch Surface Area

In SI (a = 4.267 m / 2 = 2.134 m, b = 2.591 m):

S_arc = (3.1416 / 2) * (3 * (2.134 + 2.591) - sqrt((3 * 2.134 + 2.591) * (2.134 + 3 * 2.591)))
S_arc = 1.5708 * (14.175 - sqrt(8.993 * 9.907))
S_arc = 1.5708 * (14.175 - 9.439) = 7.439 m (24.41 ft)

A_arch = 7.439 m * 7.315 m = 54.42 m² (585.8 ft²)

Step 2: Compute Both End-Wall Areas

A_end = (3.1416 / 4) * 4.267 m * 2.591 m = 8.683 m² (93.5 ft²) per end wall
2 * A_end = 17.37 m² (186.9 ft²)

Step 3: Sum Total Exposed Envelope Area

Because the arch and end walls use the same polyethylene film:

A_total = 54.42 m² + 17.37 m² = 71.79 m² (772.7 ft²)

(If the end walls were 8 mm twin-wall polycarbonate instead, keep A_arch = 54.42 m² at 4.0 or 6.8 W/(m²·K) and 2 * A_end = 17.37 m² at 3.3 W/(m²·K).)

Step 4: Calculate Steady-State Conduction Heat Loss

  • Single-layer polyethylene (6.8 W/(m²·K) / 1.20 BTU/(h·ft²·°F)):
    Q_cond = 6.8 W/(m²·K) * 71.79 m² * 16.67 K = 8,138 W (27,768 BTU/h)
    
  • Double-layer inflated polyethylene (4.0 W/(m²·K) / 0.70 BTU/(h·ft²·°F)):
    Q_cond = 4.0 W/(m²·K) * 71.79 m² * 16.67 K = 4,787 W (16,334 BTU/h)
    

At a 30°F (16.67 K) temperature lift, inflating a second layer reduces steady-state conductive heat loss by 11,434 BTU/h (3,351 W).


Verification Checks

  1. Tape vs. formula check: Compare your calculated S_arc against a physical tape measurement over the center hoop. If they differ by more than 3%, use the physical tape measurement.
  2. Inflation air-gap check: On double-layer tunnels, confirm 1–4 in (25–100 mm) of air separation at mid-span between hoops and verify that the blower intake pulls dry indoor or filtered outdoor air so condensation does not pool and collapse the gap.
  3. Skirt and end-wall seal check: Inspect the wiggle-wire channels, door sweeps, and ridge/hip transitions. Gaps that whistle or show daylight belong in air-infiltration load sizing, not conduction.

Real Failure Modes

  • Floor-area substitution: Sizing conduction from W * L (336 ft² / 31.2 m² in the example) instead of A_total (772.7 ft² / 71.8 m²) cuts the calculated load by more than half and leaves the heater unable to hold temperature during clear, calm frost nights.
  • Unpowered or collapsed double poly: Relying on 0.70 BTU/(h·ft²·°F) (4.0 W/(m²·K)) when the inflation blower is off, unplugged, or feeding a punctured outer sheet causes conductive loss to jump 70% overnight.
  • Double-counting wind: Multiplying Q_cond by a wind factor on top of adding ACH infiltration heat loss inflates the required heater size and can push electric heating loads past a 120V/15A continuous circuit budget (1,440 W).
  • Ignoring wet-film contact at the skirt: When slack inner film rests directly against the outer film near the baseboard, that lower band conducts at the single-layer rate (1.20 BTU/(h·ft²·°F) / 6.8 W/(m²·K)) and promotes condensation drip along the perimeter.