Part A and Part B Dilution and Mixing Sequence

Disperse and homogenize each liquid concentrate individually in mL into the full actual solution volume in US gal (L) in compatibility order before introducing the next part. Never pre-mix neat Part A and Part B concentrates in a measuring cup, funnel, or injection manifold, and never dose concentrates into a partially filled reservoir.

Boundary Conditions That Change the Sequence

  • Silica inclusion: Potassium silicate is strongly alkaline and polymerizes when exposed to low pH or high concentrations of calcium and magnesium. When used, add silica to the full water volume first, circulate completely, and verify pH before adding Part A.
  • High-alkalinity source water: Source water with high carbonate/bicarbonate alkalinity or starting pH above 7.5 increases the risk of calcium carbonate and calcium phosphate precipitation when Part A and Part B are introduced. Pre-condition or blend source water before mineral dosing; see the parent mixing chemistry reference for alkalinity buffering limits.
  • Solution temperature outside 65–72°F (18–22°C): Water below 60°F (15.5°C) slows salt dispersion and requires longer circulation between additions. Water at or above 75°F (24°C) lowers the dissolved oxygen ceiling and raises Pythium root-rot risk.
  • Automated vs. manual dosing: Manual batch mixing relies on reservoir pump turnover or aeration turbulence between additions. Automated inline dosing systems must physically separate Part A and Part B injection ports along the manifold with sufficient mixing length or static mixers so concentrated streams never meet undiluted.
  • Recirculating operating volume: In Dutch bucket, flood-and-drain, or NFT setups, calculate concentrate doses from the actual operating water volume in the reservoir—not the total tank capacity that includes empty headspace reserved for pump-off drain-back.

Compatibility Order and Operating Specifications

Sequence Component Typical Chemical Role Mixing Rule
1 Prepared Water Solvent at full operating volume Fill to operating mark at 65–72°F (18–22°C); start circulation
2 Silica Supplement (optional) Potassium silicate for stem strength Disperse into full volume first; circulate until uniform before Part A
3 Part A Concentrate Calcium nitrate and chelated iron Add slowly to turbulent zone; circulate until completely homogeneous
4 Calcium-Magnesium (if separate) Supplemental nitrate-form Ca/Mg Add only after verifying compatibility; never mix directly with Part B
5 Part B Concentrate Phosphates, sulfates, potassium, magnesium Add only after Part A is fully diluted; use a clean, separate cylinder
6 pH Adjuster Diluted acid or base Add last in small increments after all mineral salts equilibrate
Parameter Target Specification Engineering Note
Primary Concentration Metric EC25 (mS/cm) Temperature-referenced to 77°F (25°C)
Meter Scale Conversion 500 (NaCl) or 700 (442) ppm Meter display scale factor only, never a 40% true salt difference
ATC Meter Handling Read directly Never manually re-compensate readings from an ATC meter
Solution Temperature 65–72°F (18–22°C) >=75°F (24°C) lowers dissolved oxygen ceiling and raises Pythium risk
Target pH Range 5.5–6.5 Adjust only after full mineral homogenization

Concentrate Calculation and Illustrative Example

Calculate each concentrate volume from the actual operating water volume, not the nominal stamped size of the reservoir:

Total Concentrate (mL) = Dose Rate (mL/US gal) x Actual Operating Volume (US gal)
Total Concentrate (mL) = Dose Rate (mL/L) x Actual Operating Volume (L)
Volume Conversion: 1 US gal = 3.785 L

Illustrative assumption: A home leafy-greens Kratky or recirculating reservoir has a nominal tank size of 27 US gal (102.2 L) but is filled to an actual operating volume of 20 US gal (75.7 L) to leave headspace for root-zone air or drain-back. The nutrient datasheet specifies an illustrative mid-growth dose rate of 5.0 mL/US gal (1.32 mL/L) for Part A and 5.0 mL/US gal (1.32 mL/L) for Part B:

Part A Volume = 5.0 mL/US gal x 20 US gal = 100 mL
  (SI check: 1.321 mL/L x 75.71 L = 100 mL)

Part B Volume = 5.0 mL/US gal x 20 US gal = 100 mL
  (SI check: 1.321 mL/L x 75.71 L = 100 mL)

Before measuring, verify the actual operating water volume using physical tank graduation marks or a fill flow meter, and confirm the exact mL/US gal (mL/L) ratio on the nutrient datasheet for your crop stage.

Step-by-Step Mixing Procedure

  1. Fill and circulate: Fill the reservoir to the exact operating mark with prepared water at 65–72°F (18–22°C). Turn on the circulation pump or submerged air stones so the entire water column is actively turning over. Record baseline EC25 (mS/cm) and pH.
  2. Disperse silica (if used): Measure potassium silicate in mL and pour it slowly into the highest-turbulence zone (pump return or air-stone boil). Circulate for 5–10 minutes until fully uniform. Check pH; if silica plus source water pushes pH high enough to risk calcium precipitation, condition pH per your source-water plan before proceeding.
  3. Measure and dilute Part A: Using a clean, dry graduated cylinder or syringe, measure the required mL of Part A. Pour slowly into the turbulent mixing zone. Circulate for 5–10 minutes (or at least 2–3 full reservoir turnovers) until no density streaks or color gradients remain.
  4. Rinse or switch measuring tools: Thoroughly rinse the graduated cylinder with clean water—or use a dedicated cylinder labeled for Part B—before touching the Part B concentrate bottle.
  5. Measure and dilute Part B: Measure the required mL of Part B and pour slowly into the turbulent mixing zone. Circulate for another 5–10 minutes until completely homogenized.
  6. Verify EC25: Dip an ATC-enabled conductivity probe into the mixed reservoir and confirm the EC25 (mS/cm) matches the target for the crop stage. If EC25 is below target, add equal proportional top-up doses of Part A and Part B sequentially with full circulation between them. If EC25 is above target, dilute with prepared water.
  7. Adjust pH last: Measure pH and adjust incrementally into the 5.5–6.5 range using small doses of diluted pH adjuster, allowing at least 5 minutes of circulation before re-testing.

Verification Checks

  • Visual clarity: Inspect the solution with a flashlight. It should be clear (or uniformly tinted by chelated iron) with zero milky haze, floating flakes, or white sediment on the reservoir floor.
  • EC25 stability: Take two EC25 (mS/cm) readings 5 minutes apart with the pump running. Identical readings confirm complete homogenization rather than localized stratification.
  • pH stability: Re-check pH 15–30 minutes after the final adjustment. Rapid drift indicates ongoing carbonate buffering or incomplete mixing.
  • Emitter and substrate check: In drip setups feeding stone wool or expanded clay pebbles, verify emitter flow rates are uniform after the first irrigation cycle to confirm no precipitate is accumulating at the orifices.

Real Failure Modes

  • Calcium sulfate (gypsum) and calcium phosphate precipitation: Mixing Part A and Part B neat, pouring Part B into an un-agitated reservoir, or dosing into a half-full tank creates localized high concentrations of calcium, phosphate, and sulfate ions. They bind into insoluble white solids that settle on the tank floor, permanently stripping calcium and phosphorus from the solution while lowering EC25.
  • Silica gelation: Adding potassium silicate after Part A and Part B—or pouring concentrated acid directly into undiluted silicate—causes silicic acid to polymerize into a cloudy gel that coats roots and clogs drip emitters and stone wool pores.
  • Stock bottle cross-contamination: Using the same unwashed syringe or cup for both Part A and Part B introduces trace calcium into the Part B bottle (or phosphate/sulfate into Part A), forming crystals inside the concentrate jug and altering its delivered N-P-K and Ca ratio.
  • Nominal volume overdosing: Dosing based on the container's maximum stamped gallonage rather than the actual operating water volume spikes EC25 (mS/cm), causing osmotic root stress and tip burn.
  • False EC25 adjustments: Treating a 500 (NaCl) vs. 700 (442) ppm meter reading difference as a 40% change in true salt concentration, or applying manual temperature math to an ATC meter reading, leads to repeated over- or under-dilution.

Guides in this section (3)